GreenLine Quick-Start Guide
Pulsafeeder GreenLine DM1-6
Pump Maintenance Instructions:
• Tighten the union nut (Item 1) by hand. Do not use wrenches or other tools. Overtightening will damage the union nut and cause leakage
• Check for leakage at least once a month. If leakage is detected, address promptly to avoid corrosion of other pump components
• If the liquid crystallizes easily, regularly clean the valves to maintain performance.
• When the diaphragm is serviced or replaced, during re-assembly observe the retention plate bolt (Item 2) torque limits as shown below:
|
|
|||||||
|---|---|---|---|---|---|---|---|
|
Bolt Size
|
DM1-2 Torque
|
DM3-6 Torque
|
|||||
|
M6
|
5.6 N-m
|
50 in-lbs
|
7.9 N-m
|
70 in-lbs
|
|||
• When adjusting pump capacity (Item 3), be sure to push the handle inwards (towards the pump) before making changes.
• Contact your Pulsafeeder distributor with questions or comments
• Visit our website https://www.pulsafeeder.com or scan the QR code to find more product literature
Pulsafeeder GreenLine DM7
Pump Maintenance Instructions:
• Tighten the union nut (Item 1) by hand. Do not use wrenches or other tools. Overtightening will damage the union nut and cause leakage
• Check for leakage at least once a month. If leakage is detected, address promptly to avoid corrosion of other pump components
• If the liquid crystalizes easily, regularly clean the valves to maintain performance.
• When the diaphragm is serviced or replaced, during re-assembly observe the retention plate bolt (Item 2) torque limits as shown below:
|
|
|||||||
|---|---|---|---|---|---|---|---|
|
Bolt Size
|
DM7 Torque
|
||||||
|
M6
|
8.5 N-m
|
75 in-lbs
|
|||||
• Tighten locking screw (Item 3) immediately after stroke adjustment to avoid oil leakages
• Contact your Pulsafeeder distributor with questions or comments
• Visit our website https://www.pulsafeeder.com or scan the QR code to find more product literature