GreenLine Quick-Start Guide

Pulsafeeder GreenLine DM1-6
Pump Maintenance Instructions:

• Tighten the union nut (Item 1) by hand. Do not use wrenches or other tools. Overtightening will damage the union nut and cause leakage

• Check for leakage at least once a month. If leakage is detected, address promptly to avoid corrosion of other pump components

• If the liquid crystallizes easily, regularly clean the valves to maintain performance.

• When the diaphragm is serviced or replaced, during re-assembly observe the retention plate bolt (Item 2) torque limits as shown below:

Bolt Size
DM1-2 Torque
DM3-6 Torque
M6
5.6 N-m
50 in-lbs
7.9 N-m
70 in-lbs

• When adjusting pump capacity (Item 3), be sure to push the handle inwards (towards the pump) before making changes.

• Contact your Pulsafeeder distributor with questions or comments

 

• Visit our website https://www.pulsafeeder.com or scan the QR code to find more product literature

Pulsafeeder GreenLine DM7
Pump Maintenance Instructions:

• Tighten the union nut (Item 1) by hand. Do not use wrenches or other tools. Overtightening will damage the union nut and cause leakage

• Check for leakage at least once a month. If leakage is detected, address promptly to avoid corrosion of other pump components

• If the liquid crystalizes easily, regularly clean the valves to maintain performance.

• When the diaphragm is serviced or replaced, during re-assembly observe the retention plate bolt (Item 2) torque limits as shown below:

Bolt Size
DM7 Torque
M6
8.5 N-m
75 in-lbs

• Tighten locking screw (Item 3) immediately after stroke adjustment to avoid oil leakages

• Contact your Pulsafeeder distributor with questions or comments